Cat5E UTP/FTP Armoured Data Cable
Applications
- Cat5E Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice and data installations up to 100 MHz. In addition, these cables are with tinned copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.
Standards
-
IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004
Construction
- Conductors : 24AWG solid bare copper.
- Insulation : HDPE.
- Twinning : Two coloured insulated conductors twisted together to form a pair.
- Bedding : Flame retardant, low smoke and halogen-free polyolefin, coloured black.
- Armour : 0.2/0.3mm tinned copper wire braid.
- Outer Sheath : Low smoke and halogen-free polyolefin.
Optional
- Cat5E F/UTP : These cables have collective shielding of aluminium/Polyester tape with drain wire.
- Cat5E SF/UTP :These cables have double collective shieldings of aluminium/Polyester tape & tinned copper wire braid with drain wire
Electrical Characteristics
-
AWG 18 Nominal Conductor Diameter mm 1.0 Maximum DC Resistant@20℃ Ω/100m 9.38 Maximum DCR Unbalance % 5 Maximum Mutual Capacitance pF/m 55.8 Maximum Capacitance Unbalance pF/100m 330 Characteristic Impedance@1-100MHz Ω 100+/-15 Maximum Propagation Delay Skew ns/100m 45
-
FREQ MHz Maximum Attenuation dB/100m Minimum NEXT dB Minimum PSNEXT dB Minimum ELFEXT dB/100m Minimum PSELFEXT dB/100m Minimum RL dB 0.772 1.8 67.0 64.0 66.0 63.0 — 1 2.0 65.3 62.3 63.8 60.8 20.0 4 4.1 56.3 53.3 51.7 48.7 23.0 8 5.8 51.8 48.8 45.7 42.7 24.5 10 6.5 50.3 47.3 43.8 40.8 25.0 16 8.2 47.3 44.3 39.7 36.7 25.0 20 9.3 45.8 42.8 37.7 34.7 25.0 25 10.4 44.3 41.3 35.8 32.8 24.3 31.25 11.7 42.9 39.9 33.9 30.9 23.6 62.5 17.0 38.4 35.4 27.8 24.8 21.5 100 22.0 35.3 32.3 23.8 20.8 20.1
Mechanical and Thermal Properties
- Bending Radius : 8×OD (during installation); 4×OD (fixed installed).
- Temperature Range : -30℃ ~ +75℃.
Dimensions and Weight
Construction No. of elements×No. of cores in element×Conductor diameter (mm²) |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
|
Inner | Outer | ||||
4×2×0.53 | 0.2 | 0.8 | 1.2 | 11.2 | 208 |